Variac Drawings   

ISEinc.com  Variac.com  |   Literature & Documentation  |

  Part Number Cross Reference
 

 Variac Selector

 Portable Variacs with Cord Plug Receptacle

 Portable Variacs with Digital Volt and/or Ammeters

 Single Phase Variacs, 120VAC Input; 0-140VAC Output

 Single Phase Variacs, 120VAC Input; 0-280VAC Output

 Single Phase Variacs, 240VAC Input; 0-280VAC Output

 Single Phase Variacs, 240VAC Input; 0-560VAC Output

 Single Phase Variacs, 480VAC Input; 0-560VAC Output

 Three Phase Variacs, 240VAC Input; 0-280VAC Output

 Three Phase Variacs, 240VAC Input; 0-560VAC Output

 Three Phase Variacs, 480VAC Input; 0-560VAC Output

 Home

 Product List

 
Temperature & Process Controls

 Digital Panel Meters

 Pressure Transducers & Indicators

 Timers & Counters

 Data Loggers

 Recorders

 Variac Variable Transformers

 SCR Power Controls

 Voltage Regulators & UPS Systems

 Thermocouples

 Electric Heating Elements

 Literature List

Web Store

Repair and Calibration

Technical Data & Calculators

 

Get Acrobat Reader

Staco Variable Transformers

Return to Variable Transformer Selector

(Click on P/N for more detailed specifications)

120V Single Phase Input with up to 140V Outputs

Manually Operated P/N Motor Driven P/N Input Phase Hertz Output Constant Current Rating Constant Impedance Rating Features
171 120 1 PH 50/60 0-120 1.75A 2.2A
60 0-132 1.75A
201 120 1 PH 50/60 0-120 2.00A 2.5A
60 0-132 2.00A
221B 120 1 PH 50/60 0-120 2.50A 3.2A
60 0-132 2.50A
3PN221B 120 1 PH 60 0-132 2.50A Case, Cord, Plug, Switch, Light, Fuse, Receptacle
291 120 1 PH 50/60 0-120 3.00A 3.5A
60 0-132 3.00A
501C M501C 120 1 PH 50/60 0-120 5.0A 7.0A
0-140 5.0A
511 120 1 PH 50/60 0-120 5.0A 7.0A Smaller physical size than 501
0-140 5.0A
3PN501B 120 1 PH 50/60 0-140 5.0A Case, Cord, Plug, Switch, Light, Fuse, Receptacle
1010B M1010B 120 1 PH 50/60 0-120 10A 13A Add 'CT' Suffix for Cased version
0-140 10A
3PN1010B 120 1 PH 50/60 0-140 10A Case, Cord, Plug, Switch, Light, Fuse, Receptacle
1210B M1210B 120 1 PH 60 0-120 12A 15A Add 'CT' Suffix for Cased version
3PN1210B 120 1 PH 50/60 0-120 12A Case, Cord, Plug, Switch, Light, Fuse, Receptacle
1510B M1510B 120 1 PH 50/60 0-120 15A 20A Add 'CT' Suffix for Cased version
0-140 15A
3PN1510B 120 1 PH 50/60 0-140 15A Case, Cord, Plug, Switch, Light, Fuse, Receptacle
3PN2210B 120 1 PH 50/60 0-140 22A Case, Cord, Plug, Switch, Light, Fuse, Receptacle
2510 M2510 120 1 PH 50/60 0-120 25A 30A Add 'CT' Suffix for Cased version
0-140 25A
2510-2 M2510-2 120 1 PH 50/60 0-120 50A 60A 2-Ganged Unit, 1 51LAC Chokes Required; Add 'CT' Suffix for Cased version
0-140 50A
5011 M5011 120 1 PH 50/60 0-120 50A Add 'CT' Suffix for Cased version
0-140
6011 M6011 120 1 PH 50/60 0-120 60A Add 'CT' Suffix for Cased version
0-140
2510-3 M2510-3 120 1 PH 50/60 0-120 75A 90A 3-Ganged Unit, 3 51LAC Chokes Required; Add 'CT' Suffix for Cased version
0-140 75A
5011-2P M5011-2P 120 1 PH 50/60 0-120 100A 2-Ganged Unit; Add 'CT' Suffix for Cased version
0-140
6011-2P M6011-2P 120 1 PH 50/60 0-120 120A 2-Ganged Unit; Add 'CT' Suffix for Cased version
0-140
5011-3P M5011-3P 120 1 PH 50/60 0-120 150A 3-Ganged Unit;  Add 'E' Suffix for Enclosed version
0-140
6011-3P M6011-3P 120 1 PH 50/60 0-120 180A 3-Ganged Unit;  Add 'E' Suffix for Enclosed version
0-140
5011-4P M5011-4P 120 1 PH 50/60 0-120 200A 4-Ganged Unit;  Add 'E' Suffix for Enclosed version
0-140
6011-4P M6011-4P 120 1 PH 50/60 0-120 240A 4-Ganged Unit;  Add 'E' Suffix for Enclosed version
0-140
5011-5P M5011-5P 120 1 PH 50/60 0-120 250A 5-Ganged Unit;  Add 'E' Suffix for Enclosed version
0-140
6011-5P M6011-5P 120 1 PH 50/60 0-120 300A 5-Ganged Unit;  Add 'E' Suffix for Enclosed version
0-140
5011-6P M5011-6P 120 1 PH 50/60 0-120 300A 6-Ganged Unit;  Add 'E' Suffix for Enclosed version
0-140
5011-7P M5011-7P 120 1 PH 50/60 0-120 350A 7-Ganged Unit;  Add 'E' Suffix for Enclosed version
0-140
6011-6P M6011-6P 120 1 PH 50/60 0-120 360A 6-Ganged Unit;  Add 'E' Suffix for Enclosed version
0-140
5011-8P M5011-8P 120 1 PH 50/60 0-120 400A 8-Ganged Unit;  Add 'E' Suffix for Enclosed version
0-140
6011-7P M6011-7P 120 1 PH 50/60 0-120 420A 7-Ganged Unit;  Add 'E' Suffix for Enclosed version
0-140
5011-9P M5011-9P 120 1 PH 50/60 0-120 450A 9-Ganged Unit;  Add 'E' Suffix for Enclosed version
0-140
6011-8P M6011-8P 120 1 PH 50/60 0-120 480A 8-Ganged Unit;  Add 'E' Suffix for Enclosed version
0-140
6011-9P M6011-9P 120 1 PH 50/60 0-120 540A 9-Ganged Unit;  Add 'E' Suffix for Enclosed version
0-140

 

 

request.jpg (10520 bytes)Click on this link to request further variable transformer information

Important Notes:

CURRENT RATING TERMINOLOGY: To permit maximum utilization of STACO Variable Transformers, output ratings are given for both constant current and constant impedance loads. All current ratings are based on continuous use at ambient temperatures to 122 F (50 C).  Use derating curve for higher ambients.  Short duration overloads to 10 times transformer rating are possible.  See graph for acceptable limits.

CONSTANT CURRENT RATING: Output current that can be carried regardless of output voltage setting. (Reduce, for output above 125% of input voltage, on voltage doubler connection. See Graph)

CONSTANT IMPEDANCE RATING: Output current that can be carried with loads such as incandescent lamps or resistance heaters in which the current drawn is approximately proportional to the applied voltage, increasing to maximum current at line voltage. This rating applies only to applications where maximum output voltage is limited to line voltage.

THREE PHASE CONNECTED TRANSFORMERS: If ganged units are used in a system that ordinarily has a common neutral or ground between source and load, the neutral or ground must be connected to the common terminals of the variable transformer assembly. If the system has no neutral, the load must be balanced or the transformers will be damaged.

OPERATION AT HIGHER FREQUENCIES: All Staco variable transformers are designed for operation at 60 or 50/60 Hz.  Most models can also properly operate with input frequencies to 2000 Hz.  Some models output ratings must be derated at higher frequencies. See derating table for details.

 

 
 
 
 

[HRule Image]

Below are some links to our most popular web pages (click on the graphic to follow the link). For a complete listing click Products.

 

HOME

PRODUCTS

 

SEARCH

FEEDBACK

Track a shipment from ISE     Transit times for UPS Ground from ISE 

[HRule Image]

 

   

Headquarters
10100 Royalton Rd.,  Cleveland, OH  44133  USA
Phone: (440) 237-3200  Fax: (440) 237-1744
Email ISE Cleveland
 
Toledo Area Office
417 Tomahawk Drive,  Maumee, Oh 43537
Phone: 419-893-3330 - FAX: 419-893-2151
Email ISE Toledo  
 

ISE, Inc. Privacy Policy

Click for Cleveland, Ohio Forecast

Copyright © 2008 ISE, Inc.  All rights reserved.